Voltages, power, efficiency, resistance - the passport's fifteen public performance points
· 5 min readPoints 26 to 40 of the Commission's guidance describe the performance of the battery model, visible to everyone. Thirteen are mandatory for EV and LMT batteries, one is reserved for EVs, one is optional. Units, definitions, and where to look for the values.
The passport does not only ask who made the battery and what it is made of. It asks what it is worth: voltages, power, efficiency, expected lifetime. This data sits in Annex XIII, points 1(h) to 1(p), and the Commission's guidance of 19 October 2026 details it in fifteen points, numbered 26 to 40. All are public, and all concern the model, not the individual battery.
Voltages: three values, in volts
- Point 26 - minimum voltage, point 27 - nominal voltage, point 28 - maximum voltage, each "with temperature range when relevant". Unit: the volt, with degrees Celsius optional for the range.
Mandatory for all three categories. These are the values of the pack's datasheet; the only decision to make is to express them at pack level, not cell level, since the passport concerns the battery as placed on the market.
Power: original capability and its limits, in watts
- Point 29 - original power capability, defined by reference to Annex IV, point 3, for the batteries within the scope of that annex.
- Point 30 - power limits, "with temperature range when relevant", optionally in the form min_T °C … max_T °C.
Mandatory for all three categories. The reference to Annex IV matters: it designates the quantity "power" as the performance and durability tests define it, not a marketing figure. The value must therefore come from the Article 10 technical documentation, not from a brochure.
Lifetime: in cycles, with the test that justifies it
- Point 31 - expected lifetime, as a number of cycles. The definition is that of Article 3(1)(59).
- Point 32 - reference test used for that lifetime, as free text.
Mandatory for EV and LMT. For industrial batteries, "only applicable for some industrial batteries where lifetime can be expressed in cycles": a stationary system sized in calendar years, not in cycles, does not have to invent a figure.
Point 32 is the one most often forgotten. A lifetime without the test protocol behind it is a claim; with it, it is a verifiable data point.
The exhaustion threshold: electric vehicles only
- Point 33 - capacity threshold for exhaustion, in percent. Mandatory for EVs; "not to be filled/displayed" for LMT and industrial.
This is the remaining capacity below which the battery is considered exhausted for its original use. It only makes sense where the regulation organises an end of first life and a second life, that is, for automotive traction.
Temperature and warranty
- Point 34 - temperature range the battery can withstand when not in use (reference test), in the form min_T °C … max_T °C plus free text. Mandatory for all.
- Point 35 - period of the commercial warranty for the calendar life, in months. "If applicable", that is, if a commercial warranty is envisaged. No obligation to offer one; an obligation to declare it if it exists.
Round trip efficiency: at the start and at mid-life
- Point 36 - initial round trip energy efficiency, in percent.
- Point 37 - round trip energy efficiency at 50 % of cycle life, in percent. The definition refers to Annex II, point 2(e), the life cycle used for the carbon footprint calculation.
Mandatory for EV and LMT, "only applicable for some industrial batteries". Point 37 presupposes an ageing test carried to mid-life: this is laboratory data, which takes months to produce. To be anticipated now for the models that will be placed on the market in 2027.
Internal resistance: cell and pack
- Point 38 - internal cell resistance and internal pack resistance, in ohms. Two values under one number. Mandatory for all three categories.
A footnote of the guidance states that the system will accept multiples and submultiples of the units: the milliohm is therefore admitted, which avoids an unreadable 0.0025 Ω.
The C-rates of the cycle-life test
- Point 39 - charge C-rate of the relevant cycle-life test, as a number. Mandatory for EV and LMT, some industrial only.
- Point 40 - discharge C-rate of the same test. Optional, for all categories. Together with the manufacturer's web address, it is one of the only two truly optional points in the table.
These two points tie the declared lifetime (point 31) to the conditions of the test that produced it: a cycle count obtained at C/3 does not compare with one obtained at 2C.
And capacity?
Capacity in Ah is asked at point 11, mandatory. Point 25, "rated capacity", is marked "not to be filled: repetition of point 11". One field, one value.
What to remember
The fifteen points rest on two sources: the pack's datasheet for voltages, power, temperature range and resistance; the Annex IV performance and durability tests for lifetime, efficiency and C-rates. The first is available today at any manufacturer. The second requires tests, and a protocol to name. It is the second that sets the timetable.